In this study, a novel and simple diffractive spectrographic method for real-time measurements of circular dichroism (CD) is considered from a theoretical and experimental approach. A demonstrator prototype of the CD spectrograph has been developed and its performance has been compared with a commercial phase-modulation CD spectrometer. The main element of the device is a polarization holographic grating, recorded in a thin photosensitive organic film, by two interfering opposite circularly polarized beams. A peculiarity of this grating is that the amplitude of the +1 (-1) order of diffraction is proportional to the right (left) circular polarization component of the incoming beam. Here we demonstrate that the CD spectrum of a specimen can be easily evaluated from the intensities of the diffracted beams. A white light beam passing through the specimen is diffracted from the grating and the intensities of the +/-1 orders of diffraction are measured. Due to the spectral selectivity of the grating, the CD at each wavelength can be evaluated at the same time using two linear array detectors.

Spectrograph based on a single diffractive element for real time measurement of circular dichroism

PAGLIUSI, Pasquale;PROVENZANO C;CIPPARRONE, Gabriella
2008-01-01

Abstract

In this study, a novel and simple diffractive spectrographic method for real-time measurements of circular dichroism (CD) is considered from a theoretical and experimental approach. A demonstrator prototype of the CD spectrograph has been developed and its performance has been compared with a commercial phase-modulation CD spectrometer. The main element of the device is a polarization holographic grating, recorded in a thin photosensitive organic film, by two interfering opposite circularly polarized beams. A peculiarity of this grating is that the amplitude of the +1 (-1) order of diffraction is proportional to the right (left) circular polarization component of the incoming beam. Here we demonstrate that the CD spectrum of a specimen can be easily evaluated from the intensities of the diffracted beams. A white light beam passing through the specimen is diffracted from the grating and the intensities of the +/-1 orders of diffraction are measured. Due to the spectral selectivity of the grating, the CD at each wavelength can be evaluated at the same time using two linear array detectors.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11770/130073
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 12
social impact