A calculation code, named INLUX, able to predict the average illuminance on the inside surfaces of a room with six walls and a window, is presented. The walls and the window are subdivided into a given number of small areas, identified by the coordinates of their centres. The code solves, at each desired instant, the system of the illuminance equations of each surface element, characterized by its reflection coefficient and its view factors toward the other elements. It is assumed that all surfaces reflect the light in a diffuse manner. The model belongs to the calculation models classified as ‘‘radiosity models’’ The code was validated by comparing the calculated values of illuminance with the experimental values measured inside a scale model (1:5) of a building room, located outdoors, in overcast sky conditions. The validation, performed using the sky luminance data measured by a sky scanner as input data, showed a good performance of the code.

INLUX: A calculation code for daylight illuminance predictions inside buildings and its experimental validation

Ferraro V;KALIAKATSOS, Dimitrios;
2009-01-01

Abstract

A calculation code, named INLUX, able to predict the average illuminance on the inside surfaces of a room with six walls and a window, is presented. The walls and the window are subdivided into a given number of small areas, identified by the coordinates of their centres. The code solves, at each desired instant, the system of the illuminance equations of each surface element, characterized by its reflection coefficient and its view factors toward the other elements. It is assumed that all surfaces reflect the light in a diffuse manner. The model belongs to the calculation models classified as ‘‘radiosity models’’ The code was validated by comparing the calculated values of illuminance with the experimental values measured inside a scale model (1:5) of a building room, located outdoors, in overcast sky conditions. The validation, performed using the sky luminance data measured by a sky scanner as input data, showed a good performance of the code.
2009
Daylight, Illuminance, Buildings, Calculation codes
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11770/133181
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? ND
social impact