Synthetic polymer scaffold seeded with autologous cells have a clinical translational potential. A rational design oriented to clinical applications must ensure an efficient mass transfer of nutrients as a function of specific metabolic rates, especially for precariously vascularized tissues grown in vitro or integrated in vivo. In this work, luminescence lifetime-based sensors were used to provide accurate, extensive and non-invasive measurements of the oxygen uptake rate for human mesenchymal stem cells (hMSCs), tracheal epithelial cells (hTEpiCs) and human chondrocytes (hCCs) within a range of 2–40% O2 partial pressure. Estimated Michaelis–Menten parameters were: Vmax = 0.099 pmol/cell⋅h and KM = 2.12 × 10−7 mol/cm3 for hMSCs, Vmax = 1.23 pmol/cell⋅h and KM = 2.14 × 10−7 mol/cm3 for hTEpiCs, Vmax = 0.515 pmol/cell⋅h and KM = 1.65 × 10−7 mol/cm3 for hCCs. Kinetics data served as an input to a preliminary computational simulation of cell culture on a poly-ethylene terephthalate (PET) tracheal scaffold obtaining an efficient mass transfer at cell density of 106 cell/cm3. Oxygen concentration affected the glucose uptake and lactate production rates of cells that adapted their metabolism according to energy demand in hypoxic and normoxic conditions.

Kinetics of oxygen uptake by cells potentially used in a tissue engineered trachea

CURCIO, EFREM;
2014-01-01

Abstract

Synthetic polymer scaffold seeded with autologous cells have a clinical translational potential. A rational design oriented to clinical applications must ensure an efficient mass transfer of nutrients as a function of specific metabolic rates, especially for precariously vascularized tissues grown in vitro or integrated in vivo. In this work, luminescence lifetime-based sensors were used to provide accurate, extensive and non-invasive measurements of the oxygen uptake rate for human mesenchymal stem cells (hMSCs), tracheal epithelial cells (hTEpiCs) and human chondrocytes (hCCs) within a range of 2–40% O2 partial pressure. Estimated Michaelis–Menten parameters were: Vmax = 0.099 pmol/cell⋅h and KM = 2.12 × 10−7 mol/cm3 for hMSCs, Vmax = 1.23 pmol/cell⋅h and KM = 2.14 × 10−7 mol/cm3 for hTEpiCs, Vmax = 0.515 pmol/cell⋅h and KM = 1.65 × 10−7 mol/cm3 for hCCs. Kinetics data served as an input to a preliminary computational simulation of cell culture on a poly-ethylene terephthalate (PET) tracheal scaffold obtaining an efficient mass transfer at cell density of 106 cell/cm3. Oxygen concentration affected the glucose uptake and lactate production rates of cells that adapted their metabolism according to energy demand in hypoxic and normoxic conditions.
2014
Tissue engineered airway, Oxygen uptake rate, Tracheal scaffold
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11770/139176
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 19
social impact