In this paper, we propose a method to fully characterize noise in operational amplifiers (op-amps). The method allows the extraction not only of the spectra of the equivalent input current noise (EICN) and equivalent input voltage noise generators but also of their cross-correlation coefficients, which are routinely discarded in noise analysis of op-amps. The method is applied to extract all noise parameters of the low-noise bipolar-input op-amp OP27 and is validated through noise measurements in a test circuit. A key finding is that neglecting the cross-correlation coefficient between the two EICN generators can lead to severe errors in noise analysis.

In this paper, we propose a method to full), characterize noise in operational amplifiers (op-amps). The method allows the extraction not only of the spectra of the equivalent input current noise (EICN) and equivalent input voltage noise generators but also of their cross-correlation coefficients, which are routinely discarded in noise analysis of op-amps. The method is applied to extract all noise parameters of the low-noise bipolar-input op-amp OP27 and is validated through noise measurements in a test circuit. A key finding is that neglecting the cross-correlation coefficient between the two EICN generators can lead to severe errors in noise analysis.

Full Model and Characterization of Noise in Operational Amplifier

CRUPI, Felice;PACE, Calogero;
2009-01-01

Abstract

In this paper, we propose a method to fully characterize noise in operational amplifiers (op-amps). The method allows the extraction not only of the spectra of the equivalent input current noise (EICN) and equivalent input voltage noise generators but also of their cross-correlation coefficients, which are routinely discarded in noise analysis of op-amps. The method is applied to extract all noise parameters of the low-noise bipolar-input op-amp OP27 and is validated through noise measurements in a test circuit. A key finding is that neglecting the cross-correlation coefficient between the two EICN generators can lead to severe errors in noise analysis.
2009
In this paper, we propose a method to full), characterize noise in operational amplifiers (op-amps). The method allows the extraction not only of the spectra of the equivalent input current noise (EICN) and equivalent input voltage noise generators but also of their cross-correlation coefficients, which are routinely discarded in noise analysis of op-amps. The method is applied to extract all noise parameters of the low-noise bipolar-input op-amp OP27 and is validated through noise measurements in a test circuit. A key finding is that neglecting the cross-correlation coefficient between the two EICN generators can lead to severe errors in noise analysis.
Cross correlation; Noise measurements; Noise model; Operational amplifiers
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11770/140675
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 12
social impact