The paper summarizes the results of an experimental research, aimed at the study of the flow at a channel inlet, controlled by a sluice gate. The gate is on the wall of a tank or reservoir, of which three slopes were taken into consideration, whereas the tank bottom and the channel invert lay on the same horizontal plane. The experimental study allowed us to obtain a formula for the discharge coefficient as a function of the relative opening (ratio between the vertical sluice gate opening and the water depth into the tank); we could observe that, as to the discharge coefficient variation, the slope of the tank is negligible. Afterwards, we carried out a numerical simulation, using a software for 3-D Fluid Mechanics; the software results were validated by means of experimental observations. Using the same software we could compute discharge coefficients in an extend range of relative openings, producing a graph that can be used in the practice.

L’articolo riassume i risultati di una ricerca sperimentale indirizzata allo studio del moto all’imbocco di un canale rettangolare, controllato da paratoia piana. La paratoia è posta sulla parete di valle di una vasca o serbatoio, considerando tre inclinazioni della parete stessa, mentre il fondo del canale e quello della vasca stanno sullo stesso piano orizzontale. Lo studio sperimentale ha permesso di ottenere l’espressione del coefficiente d’efflusso in funzione dell’apertura relativa (rapporto tra l’apertura verticale della paratoia e il livello nella vasca); si è notato che, per la determinazione dei coefficienti d’efflusso, l’inclinazione della parete su cui è posta la paratoia è trascurabile. E’ stata eseguita poi una modellazione numerica con un software di fluidodinamica computazionale 3-D, validato con i risultati ottenuti sperimentalmente. Con lo stesso software sono stati calcolati i coefficienti d’efflusso in un ampio range di aperture relative della paratoia, pervenendo a un grafico utilizzabile nelle applicazioni pratiche.

Moto all'imbocco di un canale rettangolare controllato da paratoia piana - Analisi sperimentale e modellazione numerica 3D

CALOMINO, Francesco;Lauria A.
2013-01-01

Abstract

The paper summarizes the results of an experimental research, aimed at the study of the flow at a channel inlet, controlled by a sluice gate. The gate is on the wall of a tank or reservoir, of which three slopes were taken into consideration, whereas the tank bottom and the channel invert lay on the same horizontal plane. The experimental study allowed us to obtain a formula for the discharge coefficient as a function of the relative opening (ratio between the vertical sluice gate opening and the water depth into the tank); we could observe that, as to the discharge coefficient variation, the slope of the tank is negligible. Afterwards, we carried out a numerical simulation, using a software for 3-D Fluid Mechanics; the software results were validated by means of experimental observations. Using the same software we could compute discharge coefficients in an extend range of relative openings, producing a graph that can be used in the practice.
2013
L’articolo riassume i risultati di una ricerca sperimentale indirizzata allo studio del moto all’imbocco di un canale rettangolare, controllato da paratoia piana. La paratoia è posta sulla parete di valle di una vasca o serbatoio, considerando tre inclinazioni della parete stessa, mentre il fondo del canale e quello della vasca stanno sullo stesso piano orizzontale. Lo studio sperimentale ha permesso di ottenere l’espressione del coefficiente d’efflusso in funzione dell’apertura relativa (rapporto tra l’apertura verticale della paratoia e il livello nella vasca); si è notato che, per la determinazione dei coefficienti d’efflusso, l’inclinazione della parete su cui è posta la paratoia è trascurabile. E’ stata eseguita poi una modellazione numerica con un software di fluidodinamica computazionale 3-D, validato con i risultati ottenuti sperimentalmente. Con lo stesso software sono stati calcolati i coefficienti d’efflusso in un ampio range di aperture relative della paratoia, pervenendo a un grafico utilizzabile nelle applicazioni pratiche.
Efflusso da paratoia piana, Imbocco di canale, Coefficienti d’efflusso.; Underflow of a Sluice Gate, Channel Inlet, Discharge Coefficients.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11770/141758
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact