The paper presents a numerical study of the stress state which arises in the human eye with the aim of identifying some of the possible risk factors for the disease of the glaucoma. The FEM simulations were carried out by linear-elastic axisymmetric model. In the paper the risk factor taken into account were the diameter of the optical nerve head (disc – D), the ratio between this diameter and the cup of the optical nerve head (cup-to-disc ratio – C/D) and the shape of the pre-laminar tissues (varied in function of the percentage of the lamina cribrosa covered by the pre-laminar tissues). The risk was evaluated by comparing the shear strain component of the different models on the axons of the optical nerve head.
Oggetto del presente lavoro è l’impiego di metodi FEM per lo studio dello stato di sollecitazione che si sviluppa all’interno dell’occhio umano, al fine di identificare alcuni fattori di rischio per il glaucoma. Le simulazioni sono state condotte utilizzando modelli assialsimmetrici ed effettuando analisi elastiche lineari. Nel lavoro sono stati presi in esame come possibili fattori di rischio il diametro della papilla ottica (disc – D), il rapporto fra tale diametro e l’escavazione della papilla stessa (rapporto cup-to-disc – C/D), la forma dei tessuti pre-laminari (variata modificando la percentuale di lamina cribrosa coperta dai tessuti nervosi). La valutazione dei fattori di rischio è stata effettuata utilizzando come parametro di confronto la componente di deformazione tangenziale sugli assoni del nervo ottico.
Identificazione dei fattori di rischio per il glaucoma mediante metodi FEM
BRUNO, LUIGI
;Felice G;Fazio MA;Poggialini A;
2008-01-01
Abstract
The paper presents a numerical study of the stress state which arises in the human eye with the aim of identifying some of the possible risk factors for the disease of the glaucoma. The FEM simulations were carried out by linear-elastic axisymmetric model. In the paper the risk factor taken into account were the diameter of the optical nerve head (disc – D), the ratio between this diameter and the cup of the optical nerve head (cup-to-disc ratio – C/D) and the shape of the pre-laminar tissues (varied in function of the percentage of the lamina cribrosa covered by the pre-laminar tissues). The risk was evaluated by comparing the shear strain component of the different models on the axons of the optical nerve head.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.