A method is presented which allows the identification and assay of a nucleoside in the presence of other analogues and homologues. The method is based on the conventional multiple reaction monitoring approach performed on the [M+ H]+ ions of wild-type and modified nucleosides produced by the turbo ionspray ionization method on a triple-quadrupole mass spectrometer. The accuracy of the quantitative determination relies on the evaluation of a response factor r, which takes into account the kinetics of dissociation of the parent ions into the protonated [B + 2H]+ nucleobase ions. The evaluation of the absolute concentration of each analyte in the examined mixture does not require any previous chromatographic separation.
A method is presented which allows the identification and assay of a nucleoside in the presence of other analogues and homologues. The method is based on the conventional multiple reaction monitoring approach performed on the [M + H](+) ions of wild-type and modified nucleosides produced by the turbo ionspray ionization method on a triple-quadrupole mass spectrometer. The accuracy of the quantitative determination relies on the evaluation of a response factor rho, which takes into account the kinetics of dissociation of the parent ions into the protonated [B + 2H](+) nucleobase ions. The evaluation of the absolute concentration of each analyte in the examined mixture does not require any previous chromatographic separation. Copyright (C) 2003 John Wiley Sons, Ltd. OI sindona, giovanni/0000-0002-5623-5795; Benincasa, Cinzia/0000-0002-3051-2432; PERRI, ENZO/0000-0002-6314-7136
Identification and assay of wild-type ad modified nucleoside mixtures by turbo ionspray ionization tandem mass spectrometry
MAIUOLO, Loredana;Mazzotti F;SINDONA, Giovanni;
2004-01-01
Abstract
A method is presented which allows the identification and assay of a nucleoside in the presence of other analogues and homologues. The method is based on the conventional multiple reaction monitoring approach performed on the [M+ H]+ ions of wild-type and modified nucleosides produced by the turbo ionspray ionization method on a triple-quadrupole mass spectrometer. The accuracy of the quantitative determination relies on the evaluation of a response factor r, which takes into account the kinetics of dissociation of the parent ions into the protonated [B + 2H]+ nucleobase ions. The evaluation of the absolute concentration of each analyte in the examined mixture does not require any previous chromatographic separation.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.