The development of lift-off invariant strategies is one of the main goals in Eddy Current Non-Destructive Testing research. In the present work, from the analysis of amplitude and phase signals of magnetic field sensors under Multi-Frequency Eddy Current excitation, two imaging procedures are analyzed and compared with respect to their ability to retrieve reliable results even in presence of huge changes of lift-off. A figure of merit based on the Signal to Noise Ratio evaluated on the 2D reconstructed images allows the comparison of the different strategies in terms of the quality of the image to show the defect. The numerical and the experimental tests realized show that the imaging procedure relying on the analysis of the phase-lag is quite insensitive to changes in the lift-off with respect to that based on the amplitude analysis. In detail the former guarantees good results even when the probe lift-off is randomly changed during the test with variations up to 3 mm, while the latter is able to tolerate only lift-off fluctuation lower than 1 mm.

Evaluation of the lift-off robustness of eddy current imaging techniques

RICCI, MARCO;
2017-01-01

Abstract

The development of lift-off invariant strategies is one of the main goals in Eddy Current Non-Destructive Testing research. In the present work, from the analysis of amplitude and phase signals of magnetic field sensors under Multi-Frequency Eddy Current excitation, two imaging procedures are analyzed and compared with respect to their ability to retrieve reliable results even in presence of huge changes of lift-off. A figure of merit based on the Signal to Noise Ratio evaluated on the 2D reconstructed images allows the comparison of the different strategies in terms of the quality of the image to show the defect. The numerical and the experimental tests realized show that the imaging procedure relying on the analysis of the phase-lag is quite insensitive to changes in the lift-off with respect to that based on the amplitude analysis. In detail the former guarantees good results even when the probe lift-off is randomly changed during the test with variations up to 3 mm, while the latter is able to tolerate only lift-off fluctuation lower than 1 mm.
File in questo prodotto:
File Dimensione Formato  
PREPRINT Evaluation of the Lift-off Robustness of Eddy Current Imaging Techniques.pdf

accesso aperto

Descrizione: This document is the pre-print version of the manuscript Ricci, M., Silipigni, G., Ferrigno, L., Laracca, M., Adewale, I. D., & Tian, G. Y. (2017). Evaluation of the lift-off robustness of eddy current imaging techniques. NDT & E International, 85, 43-52; DOI: 10.1016/j.ndteint.2016.10.001
Tipologia: Documento in Pre-print
Licenza: Creative commons
Dimensione 1.37 MB
Formato Adobe PDF
1.37 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11770/133053
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 36
  • ???jsp.display-item.citation.isi??? 30
social impact