Technologically-enhanced electronic image sensors are used in various fields as diagnostic techniques in medicine or space applications. In the latter case the devices can be exposed to intense radiation fluxes over time which may impair the functioning of the same equipment. In this paper we report the results of gamma-ray irradiation tests on CMOS image sensors simulating the space radiation over a long time period. Gamma-ray irradiation tests were carried out by means of IGS-3 gamma irradiation facility of Palermo University, based on 60Co sources with different activities. To re duce the dose rate and realize a narrow gamma-ray beam, a lead-collimation system was purposely built. It permits to have dose rate values less than 10 mGy/s and to irradiate CMOS Image Sensors during operation. The total ionizing dose to CMOS image sensors was monitored in-situ, during irradiation, up to 1000 Gy and images were acquired every 25 Gy. At the end of the tests, the sensors continued to operate despite a back ground noise and some pixels were completely saturated. These effects, however, involve isolated pixels and therefore, should not affect the image quality.

GAMMA-RAY IRRADIATION TESTS OF CMOS SENSORS USED IN IMAGING TECHNIQUES

PACE, Calogero;
2014-01-01

Abstract

Technologically-enhanced electronic image sensors are used in various fields as diagnostic techniques in medicine or space applications. In the latter case the devices can be exposed to intense radiation fluxes over time which may impair the functioning of the same equipment. In this paper we report the results of gamma-ray irradiation tests on CMOS image sensors simulating the space radiation over a long time period. Gamma-ray irradiation tests were carried out by means of IGS-3 gamma irradiation facility of Palermo University, based on 60Co sources with different activities. To re duce the dose rate and realize a narrow gamma-ray beam, a lead-collimation system was purposely built. It permits to have dose rate values less than 10 mGy/s and to irradiate CMOS Image Sensors during operation. The total ionizing dose to CMOS image sensors was monitored in-situ, during irradiation, up to 1000 Gy and images were acquired every 25 Gy. At the end of the tests, the sensors continued to operate despite a back ground noise and some pixels were completely saturated. These effects, however, involve isolated pixels and therefore, should not affect the image quality.
2014
imaging technique; CMOS image sensors; gamma irradiation
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11770/142256
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact