The analysis of characteristic urinary acidic markers such as glutaric, 3-hydroxyglutaric, 2-hydroxyglutaric, adipic, suberic, sebacic, ethylmalonic, 3-hydroxyisovaleric and isobutyric acid constitutes the recommended follow-up testing procedure for glutaric acidemia type 1 (GA-1) and type 2 (GA-2). The goal of the work herein presented is the development of a fast and simple method for the quantification of these biomarkers in human urine. The proposed analytical approach is based on the use of solid phase microextraction (SPME) combined with gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS) afterward a rapid derivatization of acidic moieties by propyl chloroformate, propanol and pyridine. Trueness and precision of the proposed protocol, tested at 5,30 and 80 mg l(-1), provided satisfactory values: recoveries were in the range between 72% and 116% and the relative standard deviations (RSD%) were between 0.9% and 18% (except for isobutyric acid at 5 mg l(-1)). The LOD values achieved by the proposed method ranged between 1.0 and 473 mu g l(-1). (C) 2014 Elsevier B.V. All rights reserved. OI Gionfriddo, Emanuela/0000-0002-1836-1950; sindona, giovanni/0000-0002-5623-5795; NACCARATO, Attilio/0000-0001-5799-5369; Tagarelli, Antonio/0000-0002-8811-1631
A fast and simple solid phase microextraction coupled with gas chromatography-triple quadrupole mass spectrometry method for the assay of urinary markers of glutaric acidemias
Naccarato A;Elliani R;SINDONA, Giovanni;TAGARELLI, Antonio
2014-01-01
Abstract
The analysis of characteristic urinary acidic markers such as glutaric, 3-hydroxyglutaric, 2-hydroxyglutaric, adipic, suberic, sebacic, ethylmalonic, 3-hydroxyisovaleric and isobutyric acid constitutes the recommended follow-up testing procedure for glutaric acidemia type 1 (GA-1) and type 2 (GA-2). The goal of the work herein presented is the development of a fast and simple method for the quantification of these biomarkers in human urine. The proposed analytical approach is based on the use of solid phase microextraction (SPME) combined with gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS) afterward a rapid derivatization of acidic moieties by propyl chloroformate, propanol and pyridine. Trueness and precision of the proposed protocol, tested at 5,30 and 80 mg l(-1), provided satisfactory values: recoveries were in the range between 72% and 116% and the relative standard deviations (RSD%) were between 0.9% and 18% (except for isobutyric acid at 5 mg l(-1)). The LOD values achieved by the proposed method ranged between 1.0 and 473 mu g l(-1). (C) 2014 Elsevier B.V. All rights reserved. OI Gionfriddo, Emanuela/0000-0002-1836-1950; sindona, giovanni/0000-0002-5623-5795; NACCARATO, Attilio/0000-0001-5799-5369; Tagarelli, Antonio/0000-0002-8811-1631I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.