A calculation code, named INLUX-DBR, is presented, which is a modified version of INLUX code, able to predict the illuminance distribution on the inside surfaces of a room with six walls and a window, and on the work plane. At each desired instant the code solves the system of the illuminance equations of each surface element, characterized by the latter’s reflection coefficient and its view factors toward the other elements. In the model implemented in the code, the sky-diffuse luminance distribution, the sun beam light and the light reflected from the ground toward the room are considered.The code was validated by comparing the calculated values of illuminance with the experimental values measured inside a scale model (1:5) of a building room, in various sky conditions of overcast, clear and intermediate days. The validation is performed using the sky luminance data measured by a sky scanner and the measured beam illuminance of the sun as input data.A comparative analysis of some of the well-known calculation models of sky luminance, namely Perez, Igawa and CIE models was also carried out, comparing the code predictions and the measured values of inside illuminance in the scale model.

INLUX-DBR e A calculation code to calculate indoor natural illuminance inside buildings under various sky conditions

FERRARO, VITTORIO;
2010-01-01

Abstract

A calculation code, named INLUX-DBR, is presented, which is a modified version of INLUX code, able to predict the illuminance distribution on the inside surfaces of a room with six walls and a window, and on the work plane. At each desired instant the code solves the system of the illuminance equations of each surface element, characterized by the latter’s reflection coefficient and its view factors toward the other elements. In the model implemented in the code, the sky-diffuse luminance distribution, the sun beam light and the light reflected from the ground toward the room are considered.The code was validated by comparing the calculated values of illuminance with the experimental values measured inside a scale model (1:5) of a building room, in various sky conditions of overcast, clear and intermediate days. The validation is performed using the sky luminance data measured by a sky scanner and the measured beam illuminance of the sun as input data.A comparative analysis of some of the well-known calculation models of sky luminance, namely Perez, Igawa and CIE models was also carried out, comparing the code predictions and the measured values of inside illuminance in the scale model.
2010
ndoor natural illuminance All sky conditions
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11770/153220
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact