The first Barrel Inner Large chamber of the Monitored Drift Tube (MDT) tracking detector for the muon spectrometer of the ATLAS experiment has been tested with a high-energy muon beam. After a description of the MDT characteristics, we present the test beam experimental set-up, the data analysis techniques and discuss the results. The chamber was operated with a Ar(93%)-CO2(7%) gas mixture at 3-bar pressure. The performance studies include the chamber calibration, the single-tube resolution, efficiency and electronic noise, and their behaviour as a function of the high-voltage setting and discriminator threshold. (C) 2003 Elsevier B.V. All rights reserved.
Test of the first BIL tracking chamber for the ATLAS muon spectrometer
Avolio, G;La Rotonda, L;Meoni, E;
2004-01-01
Abstract
The first Barrel Inner Large chamber of the Monitored Drift Tube (MDT) tracking detector for the muon spectrometer of the ATLAS experiment has been tested with a high-energy muon beam. After a description of the MDT characteristics, we present the test beam experimental set-up, the data analysis techniques and discuss the results. The chamber was operated with a Ar(93%)-CO2(7%) gas mixture at 3-bar pressure. The performance studies include the chamber calibration, the single-tube resolution, efficiency and electronic noise, and their behaviour as a function of the high-voltage setting and discriminator threshold. (C) 2003 Elsevier B.V. All rights reserved.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.