Gait analysis has become an important tool for diagnosing disease and evaluating disease progression. Currently gait analysis were mainly conducted by experienced physicians and rely on medical observation or complex medical equipment, hence the application has been limited. This research aims to build an ambulatory gait analysis system based on the emerging body sensor networks (BSN). A Calibration method for magnetometer was proposed to deal with ubiquitous a magnetic disturbance. Proportional integral controller based complementary filter and error correction of gait parameters have been defined with multilevel data fusion algorithm. Preliminary gait analysis trials were conducted on both healthy subjects and patients with abnormal gait. Experimental results indicated that the proposed scheme has significant advantages in terms of test accuracy and efficiency, as well as operation complexity compared to conventional gait analysis approaches. Accordingly, measurement of gait abnormality may provide a wealth of information regarding neuromotor status and characterization of some neurological disorders. It is concluded that the proposed gait analysis system has great potential as an auxiliary for medical rehabilitation.

Body Sensor Network-based Robust Gait Analysis: Toward Clinical and at Home Use

Fortino, Giancarlo
2019-01-01

Abstract

Gait analysis has become an important tool for diagnosing disease and evaluating disease progression. Currently gait analysis were mainly conducted by experienced physicians and rely on medical observation or complex medical equipment, hence the application has been limited. This research aims to build an ambulatory gait analysis system based on the emerging body sensor networks (BSN). A Calibration method for magnetometer was proposed to deal with ubiquitous a magnetic disturbance. Proportional integral controller based complementary filter and error correction of gait parameters have been defined with multilevel data fusion algorithm. Preliminary gait analysis trials were conducted on both healthy subjects and patients with abnormal gait. Experimental results indicated that the proposed scheme has significant advantages in terms of test accuracy and efficiency, as well as operation complexity compared to conventional gait analysis approaches. Accordingly, measurement of gait abnormality may provide a wealth of information regarding neuromotor status and characterization of some neurological disorders. It is concluded that the proposed gait analysis system has great potential as an auxiliary for medical rehabilitation.
2019
Body Sensor Network; Calibration; Gait Analysis; Inertial Sensors; Information Fusion; Legged locomotion; Magnetic sensors; Magnetometers; Magnetometric Calibration; Sensor phenomena and characterization; Sensor systems; Instrumentation; Electrical and Electronic Engineering
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11770/285174
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 32
  • ???jsp.display-item.citation.isi??? 25
social impact