Efficient low consumption buildings require the building envelope to be scrupulously designed from an early stage. Passive solar technologies, such as the Trombe wall, can contribute to the reduction of the heating energy demand and, if properly operated, they can also impact the building summer behaviour. The use of such a solution has been limited, especially in warm climates, as severe problems of indoor overheating can occur even beyond the cooling period. Through the dynamic simulation software DesignBuilder, the authors investigated the energy performance of two different residential buildings equipped with a Trombe wall in different climatic contexts. The authors proposed the adoption of proper ventilation strategies to further reduce cooling needs. The validity and effectiveness of the proposed solutions was verified in warm climates where the Trombe reduced heating requirements by up to 71.7% and decreased the cooling energy demand by 36.1%. In a cold climate, heating savings were 18.2% with a cooling energy reduction of 42.4%. The study highlighted the fundamental importance of the definition of proper ventilation strategies based on climatic parameters to prevent drawbacks in intermediate seasons, with an evident limitation of the system performance.

Are Trombe walls suitable passive systems for the reduction of the yearly building energy requirements?

Bevilacqua P.;Benevento F.;Bruno R.;Arcuri N.
2019-01-01

Abstract

Efficient low consumption buildings require the building envelope to be scrupulously designed from an early stage. Passive solar technologies, such as the Trombe wall, can contribute to the reduction of the heating energy demand and, if properly operated, they can also impact the building summer behaviour. The use of such a solution has been limited, especially in warm climates, as severe problems of indoor overheating can occur even beyond the cooling period. Through the dynamic simulation software DesignBuilder, the authors investigated the energy performance of two different residential buildings equipped with a Trombe wall in different climatic contexts. The authors proposed the adoption of proper ventilation strategies to further reduce cooling needs. The validity and effectiveness of the proposed solutions was verified in warm climates where the Trombe reduced heating requirements by up to 71.7% and decreased the cooling energy demand by 36.1%. In a cold climate, heating savings were 18.2% with a cooling energy reduction of 42.4%. The study highlighted the fundamental importance of the definition of proper ventilation strategies based on climatic parameters to prevent drawbacks in intermediate seasons, with an evident limitation of the system performance.
2019
Building energy efficiency; Dynamic simulations; Passive solar system; Trombe wall; Ventilation strategies
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11770/295617
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 56
  • ???jsp.display-item.citation.isi??? 52
social impact