In this work, a geochemical approach was used as strong-scientific tool for pre-selection of suitable remediation systems to treat Cr-contaminated groundwaters. The geochemical characterization allowed to select Nanofiltration (NF) and Reverse Osmosis (RO) as suitable remediation processes, whereas through a new geochemical modeling, the evolution of water chemistry during the water-rock interaction was also studied. The new reaction path modelling was performed re-evaluating the role of Fe as main oxidant in the system and the analytic concentrations of relevant solutes, including Cr(VI), were reproduced. The spring with the highest Cr(VI) content was treated to lower its concentration below the threshold values. A laboratory-scale set-up was used to carry out both NF and RO experiments. The experiments were conducted on different commercial membranes varying the operating pressures. The results showed high Cr(VI) rejections (around 95%) for all tested membranes, leading to Cr(VI) concentrations below the threshold limits. The high flux, obtained already at lower operating pressures, combined with high selectivity towards Cr(VI) makes NF a favorable remediation option.

Geochemical modeling of chromium release in natural waters and treatment by RO/NF membrane processes

I. Fuoco;A. Figoli;A. Criscuoli;R. De Rosa;B. Gabriele;C. Apollaro
2020-01-01

Abstract

In this work, a geochemical approach was used as strong-scientific tool for pre-selection of suitable remediation systems to treat Cr-contaminated groundwaters. The geochemical characterization allowed to select Nanofiltration (NF) and Reverse Osmosis (RO) as suitable remediation processes, whereas through a new geochemical modeling, the evolution of water chemistry during the water-rock interaction was also studied. The new reaction path modelling was performed re-evaluating the role of Fe as main oxidant in the system and the analytic concentrations of relevant solutes, including Cr(VI), were reproduced. The spring with the highest Cr(VI) content was treated to lower its concentration below the threshold values. A laboratory-scale set-up was used to carry out both NF and RO experiments. The experiments were conducted on different commercial membranes varying the operating pressures. The results showed high Cr(VI) rejections (around 95%) for all tested membranes, leading to Cr(VI) concentrations below the threshold limits. The high flux, obtained already at lower operating pressures, combined with high selectivity towards Cr(VI) makes NF a favorable remediation option.
2020
Hexavalent chromium, Ophiolitic aquifer, Trivalent iron, Contaminated waters, Nanofiltration Reverse osmosis
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11770/304816
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 41
  • ???jsp.display-item.citation.isi??? 33
social impact