This paper presents the muon momentum calibration and performance studies for the ATLAS detector based on the pp collisions data sample produced at root s = 13 TeV at the LHC during Run 2 and corresponding to an integrated luminosity of 139 fb(-1). An innovative approach is used to correct for potential charge-dependent momentum biases related to the knowledge of the detector geometry, using the Z ->mu(+)mu(-) resonance. The muon momentum scale and resolution are measured using samples of J/psi ->mu(+)mu(-) and Z ->mu(+)mu(-) events. A calibration procedure is defined and applied to simulated data to match the performance measured in real data. The calibration is validated using an independent sample of Upsilon ->mu(+)mu(-) events. At the Z(J/psi) peak, the momentum scale is measured with an uncertainty at the 0.05% (0.1%) level, and the resolution is measured with an uncertainty at the 1.5% (2%) level. The charge-dependent bias is removed with a dedicated in situ correction for momenta up to 450 GeV with a precision better than 0.03 TeV-1.

Studies of the muon momentum calibration and performance of the ATLAS detector with $pp$ collisions at $\sqrt{s}$=13 TeV

Capua, M;Mastroberardino, A;Meoni, E;Schioppa, M;Tassi, E;
2022-01-01

Abstract

This paper presents the muon momentum calibration and performance studies for the ATLAS detector based on the pp collisions data sample produced at root s = 13 TeV at the LHC during Run 2 and corresponding to an integrated luminosity of 139 fb(-1). An innovative approach is used to correct for potential charge-dependent momentum biases related to the knowledge of the detector geometry, using the Z ->mu(+)mu(-) resonance. The muon momentum scale and resolution are measured using samples of J/psi ->mu(+)mu(-) and Z ->mu(+)mu(-) events. A calibration procedure is defined and applied to simulated data to match the performance measured in real data. The calibration is validated using an independent sample of Upsilon ->mu(+)mu(-) events. At the Z(J/psi) peak, the momentum scale is measured with an uncertainty at the 0.05% (0.1%) level, and the resolution is measured with an uncertainty at the 1.5% (2%) level. The charge-dependent bias is removed with a dedicated in situ correction for momenta up to 450 GeV with a precision better than 0.03 TeV-1.
2022
High Energy Physics - Experiment
High Energy Physics - Experiment
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11770/361331
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 4
social impact