Extracorporeal Membrane Oxygenation (ECMO) is a medical device used to support patients with severe cardiac and/or respiratory failure. It is being used more frequently to offer percutaneous mechanical circulatory support, even though the intricate interactions between ECMO and the failing heart, as well as its impact on hemodynamics and perfusion, are not yet fully understood. Within the two main types of ECMO support (the veno-venous ECMO (VV-ECMO), which is used to support only the lungs) and the veno-arterial ECMO (VA-ECMO), which is used to support the lungs and heart), consideration is given solely to the second approach. Indeed, this study focuses on the impact of different ECMO cannulation site and blood perfusion conditions on the aortic hemodynamics and organ perfusion in VA-ECMO. Using computed tomography (CT) images, we reconstructed specific aortic models based on clinical cannula configurations and placements. A detailed cannula-aorta integration model was developed to simulate the VA-ECMO blood supply environment. Employing computational fluid dynamics (CFD), we analyzed how varying ECMO perfusion levels and ECMO cannulation sites affect flow characteristics. This study provides insights into optimizing ECMO therapy by understanding its effects on blood flow and potential damage to blood and organs.

The Influence of Different ECMO Cannulation Site and Blood Perfusion Conditions on the Aortic Hemodynamics: A Computational Fluid Dynamic Model

Gramigna V.;Palumbo A.;Fragomeni G.
2024-01-01

Abstract

Extracorporeal Membrane Oxygenation (ECMO) is a medical device used to support patients with severe cardiac and/or respiratory failure. It is being used more frequently to offer percutaneous mechanical circulatory support, even though the intricate interactions between ECMO and the failing heart, as well as its impact on hemodynamics and perfusion, are not yet fully understood. Within the two main types of ECMO support (the veno-venous ECMO (VV-ECMO), which is used to support only the lungs) and the veno-arterial ECMO (VA-ECMO), which is used to support the lungs and heart), consideration is given solely to the second approach. Indeed, this study focuses on the impact of different ECMO cannulation site and blood perfusion conditions on the aortic hemodynamics and organ perfusion in VA-ECMO. Using computed tomography (CT) images, we reconstructed specific aortic models based on clinical cannula configurations and placements. A detailed cannula-aorta integration model was developed to simulate the VA-ECMO blood supply environment. Employing computational fluid dynamics (CFD), we analyzed how varying ECMO perfusion levels and ECMO cannulation sites affect flow characteristics. This study provides insights into optimizing ECMO therapy by understanding its effects on blood flow and potential damage to blood and organs.
2024
aortic hemodynamics
computational fluid dynamics
extracorporeal membrane oxygenation
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11770/401460
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 2
social impact