Intraaortic balloon pump (IABP) is used as temporary mechanical assistance in case of cardiovascular diseases, even if different hemodynamic problems and, thus, clinical complications may happen, such as the decrease of visceral perfusion. A computational fluid dynamic (CFD) study was carried out to investigate the effects of different IABP-induced abdominal occlusions on patient-specific aortic flow. Two possible sizes (25 and 34 cm3) and two locations (2 and 3 cm) of the balloon were compared, modeling four abdominal occlusions and numerically reproducing IAB inflation/deflation behavior. The results highlighted that the perfusion in renal, mesenteric, and iliac arteries decreases when the abdominal occlusion increases with balloon inflation. The study illustrates also how the balloon size affects the flow in aorta vessels in both locations, and that the positioning is of little relevance for the 34 cm3 balloon, whereas it influences the aortic flow very much in case of 25 cm3 IAB. This analysis demonstrates how the IAB-induced occlusion may vary the abdominal circulation; therefore, the correct size and positioning are emphasized for patient's outcome.

Influence of IABP-Induced Abdominal Occlusions on Aortic Hemodynamics: A Patient-Specific Computational Evaluation

Caruso M. V.;Fragomeni G.
2017-01-01

Abstract

Intraaortic balloon pump (IABP) is used as temporary mechanical assistance in case of cardiovascular diseases, even if different hemodynamic problems and, thus, clinical complications may happen, such as the decrease of visceral perfusion. A computational fluid dynamic (CFD) study was carried out to investigate the effects of different IABP-induced abdominal occlusions on patient-specific aortic flow. Two possible sizes (25 and 34 cm3) and two locations (2 and 3 cm) of the balloon were compared, modeling four abdominal occlusions and numerically reproducing IAB inflation/deflation behavior. The results highlighted that the perfusion in renal, mesenteric, and iliac arteries decreases when the abdominal occlusion increases with balloon inflation. The study illustrates also how the balloon size affects the flow in aorta vessels in both locations, and that the positioning is of little relevance for the 34 cm3 balloon, whereas it influences the aortic flow very much in case of 25 cm3 IAB. This analysis demonstrates how the IAB-induced occlusion may vary the abdominal circulation; therefore, the correct size and positioning are emphasized for patient's outcome.
2017
abdominal occlusion
computational fluid dynamics
hemodynamics
intraaortic balloon pump
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11770/401463
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 14
social impact