We have designed and tested a very low-noise, high-accuracy programmable voltage reference that is intended as an alternative to batteries for the realization of automated low-frequency noise measurement systems. The output voltage, which can be set via a built-in RS232 interface, ranges from 0 to 5 V with a resolution and long-term stability of +/-250 muV. The power spectral density of the output voltage fluctuations is less than 2(.)10(-16) V-2/Hz at 100 mHz and remains below 10(-17) V-2/Hz above 1 Hz.

We have designed and tested a very low-noise, high-accuracy programmable voltage reference that is intended as an alternative to batteries for the realization of automated low-frequency noise measurement systems. The output voltage, which can be set via a built-in RS232 interface, ranges from 0 to 5 V with a resolution and long-term stability of +/-250 muV. The power spectral density of the output voltage fluctuations is less than 2(.)10(-16) V-2/Hz at 100 mHz and remains below 10(-17) V-2/Hz above 1 Hz.

Very low noise, high accuracy, programmable voltage reference

PACE, Calogero;CRUPI, Felice
2003-01-01

Abstract

We have designed and tested a very low-noise, high-accuracy programmable voltage reference that is intended as an alternative to batteries for the realization of automated low-frequency noise measurement systems. The output voltage, which can be set via a built-in RS232 interface, ranges from 0 to 5 V with a resolution and long-term stability of +/-250 muV. The power spectral density of the output voltage fluctuations is less than 2(.)10(-16) V-2/Hz at 100 mHz and remains below 10(-17) V-2/Hz above 1 Hz.
2003
We have designed and tested a very low-noise, high-accuracy programmable voltage reference that is intended as an alternative to batteries for the realization of automated low-frequency noise measurement systems. The output voltage, which can be set via a built-in RS232 interface, ranges from 0 to 5 V with a resolution and long-term stability of +/-250 muV. The power spectral density of the output voltage fluctuations is less than 2(.)10(-16) V-2/Hz at 100 mHz and remains below 10(-17) V-2/Hz above 1 Hz.
Automatic testing; Low-frequency measurements; Low-noise instrumentation; Spectral analysis; Voltage reference
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11770/138379
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 27
  • ???jsp.display-item.citation.isi??? 21
social impact