The aim of this study was to evaluate the performance of different analytic methods, such as liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS), high-performance liquid chromatography-ultraviolet (HPLC-UV), enzyme-linked immunosorbent assay (EIA), and chemiluminescence immunoassays (CLIA), in order to highlight whether or not there is relative superiority amongst the assays. We analyzed two groups of subjects suffering from headache and two groups of healthy subjects. We performed a prospective, single-blind single-center control-group study on 220 subjects with migraine. Subjects of both sexes >10 years old and with 12 months' history of migraine were eligible for the study. The mean values measured using HPLC-UV, EIA, and CLIA tests such as Liaison® and Architect® did not show significant differences compared to the values obtained using LC-MS/MS. In conclusion, the population generally has low values of the vitamin D3 hormone, and the suggested range should probably be revised. HPLC-UV and CLIA were found to have appropriate analytical values compared to the reference method (LC-MS/MS), so it is possible to suggest their routine use to optimize care.
25-Hydroxy Vitamin D Detection Using Different Analytic Methods in Patients with Migraine
Cione E.;Fazio A.;
2019-01-01
Abstract
The aim of this study was to evaluate the performance of different analytic methods, such as liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS), high-performance liquid chromatography-ultraviolet (HPLC-UV), enzyme-linked immunosorbent assay (EIA), and chemiluminescence immunoassays (CLIA), in order to highlight whether or not there is relative superiority amongst the assays. We analyzed two groups of subjects suffering from headache and two groups of healthy subjects. We performed a prospective, single-blind single-center control-group study on 220 subjects with migraine. Subjects of both sexes >10 years old and with 12 months' history of migraine were eligible for the study. The mean values measured using HPLC-UV, EIA, and CLIA tests such as Liaison® and Architect® did not show significant differences compared to the values obtained using LC-MS/MS. In conclusion, the population generally has low values of the vitamin D3 hormone, and the suggested range should probably be revised. HPLC-UV and CLIA were found to have appropriate analytical values compared to the reference method (LC-MS/MS), so it is possible to suggest their routine use to optimize care.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.