Fall incidents represent a major public health problem among elderly people. This resulted in a significant increase of the number of investigated systems aiming at detecting falls promptly. In this respect, in this work, a biomedical radar system is proposed for remote real-time fall detection and indoor localization. The system, consisting of a sensor and a base station, combines radar and wireless communication techniques, and uses a data processing technique to distinguish between fall events and normal movements. The classification, based on a Least-Square Support Vector Machine (LS -SVM), combined with the sliding window principle allows to perform fall detection in real-time. Moreover, it is capable to localize the subjects when the fall incident has been detected. The in-vivo validation showed a high success rate in detecting fall events, with a maximum delay of 340 ms. Moreover, a maximum mean absolute errors (MAE) of 3.8 cm and a maximum root-mean-square error (RMSE) of 7.5 cm were reported in measuring the subject's absolute distance.

Biomedical Radar System for Real-Time Contactless Fall Detection and Indoor Localization

Mercuri, Marco
;
Crupi, Felice;Schreurs, Dominique
2023-01-01

Abstract

Fall incidents represent a major public health problem among elderly people. This resulted in a significant increase of the number of investigated systems aiming at detecting falls promptly. In this respect, in this work, a biomedical radar system is proposed for remote real-time fall detection and indoor localization. The system, consisting of a sensor and a base station, combines radar and wireless communication techniques, and uses a data processing technique to distinguish between fall events and normal movements. The classification, based on a Least-Square Support Vector Machine (LS -SVM), combined with the sliding window principle allows to perform fall detection in real-time. Moreover, it is capable to localize the subjects when the fall incident has been detected. The in-vivo validation showed a high success rate in detecting fall events, with a maximum delay of 340 ms. Moreover, a maximum mean absolute errors (MAE) of 3.8 cm and a maximum root-mean-square error (RMSE) of 7.5 cm were reported in measuring the subject's absolute distance.
2023
Contactless
fall detection
movement classification
radar remote sensing
real-time health monitoring
tagless localization
zigbee communication
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11770/354817
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 5
social impact