In this paper, the influence of the strengthening configuration on the structural response of U-wrapped SRG (Steel-Reinforced Grout) shear-strengthened reinforced concrete beams was analyzed both experimentally and theoretically. The parameters varied were the ratio sf/wf, sf being the distance between two consecutive U-shaped strips and wf the width of the strips, and the number of steel fabric layers (one and two). Two series of real-scale beams, eleven beams in total with one un-strengthened and ten strengthened, were tested up to failure (the results obtained in the first series of tests were reported in a previously published paper). The obtained results highlighted that the debonding phenomena, which occurred for all the examined strengthening configurations, strongly affected the shear capacity of strengthened beams. An analytical model found based on the “effective strain” of the SRG strips was developed to predict the shear capacity of SRG shear-strengthened reinforced concrete beams. Two analytical relationships were proposed to evaluate the “effective strain” of the SRG strips: The first one was based on a statistical analysis of results obtained by tests on FRCM (Fabric-Reinforced Cementitious Mortar) and SRG shear-strengthened reinforced concrete beams, while the second was developed through the results of single lap direct shear tests performed on SRG-to-concrete joints. The effectiveness of the proposed analytical metho

Influence of the strengthening configuration on the shear capacity of reinforced concrete beams strengthened with SRG (Steel-Reinforced Grout) composites

Ombres Luciano
Membro del Collaboration Group
;
Verre Salvatore
Membro del Collaboration Group
2022-01-01

Abstract

In this paper, the influence of the strengthening configuration on the structural response of U-wrapped SRG (Steel-Reinforced Grout) shear-strengthened reinforced concrete beams was analyzed both experimentally and theoretically. The parameters varied were the ratio sf/wf, sf being the distance between two consecutive U-shaped strips and wf the width of the strips, and the number of steel fabric layers (one and two). Two series of real-scale beams, eleven beams in total with one un-strengthened and ten strengthened, were tested up to failure (the results obtained in the first series of tests were reported in a previously published paper). The obtained results highlighted that the debonding phenomena, which occurred for all the examined strengthening configurations, strongly affected the shear capacity of strengthened beams. An analytical model found based on the “effective strain” of the SRG strips was developed to predict the shear capacity of SRG shear-strengthened reinforced concrete beams. Two analytical relationships were proposed to evaluate the “effective strain” of the SRG strips: The first one was based on a statistical analysis of results obtained by tests on FRCM (Fabric-Reinforced Cementitious Mortar) and SRG shear-strengthened reinforced concrete beams, while the second was developed through the results of single lap direct shear tests performed on SRG-to-concrete joints. The effectiveness of the proposed analytical metho
2022
reinforced concrete; beams; shear strengthening; SRG; modelling
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.11770/356738
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? ND
social impact