This work introduces a compact voltage reference operating at pW-power and 250-mV supply (e.g., direct harvester-powered). Body biasing assisted by replica biasing enables 25μV/°C temperature coefficient, 140μV/V line sensitivity, and 0.42mV process sensitivity in 180nm. 2.55-mV overall accuracy is achieved at 2,200μm2 area, without trimming.
A 0.25-V, 5.3-pW Voltage Reference with 25-μV/°C Temperature Coefficient, 140-μV/V Line Sensitivity and 2,200-μm2 Area in 180nm
Fassio L.;De Rose R.;Lanuzza M.;Crupi F.;
2020-01-01
Abstract
This work introduces a compact voltage reference operating at pW-power and 250-mV supply (e.g., direct harvester-powered). Body biasing assisted by replica biasing enables 25μV/°C temperature coefficient, 140μV/V line sensitivity, and 0.42mV process sensitivity in 180nm. 2.55-mV overall accuracy is achieved at 2,200μm2 area, without trimming.File in questo prodotto:
Non ci sono file associati a questo prodotto.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.